poe:PhysIf

Power on Ethernet Interface

Telemetry Sensor Path(s)

Configurable Properties
PROPERTY NAME DATA TYPE DESCRIPTION PERMITTED VALUES
maxConsumption poe:poeMaxConsumption
(scalar:Uint64)
POE interface's current max port consumption
RANGE: [4000 , 60000]
DEFAULT: 30000
portDefaultConsumption poe:poeDefaultConsumption
(scalar:Uint64)
POE interface's default port consumption
RANGE: [4000 , 30000]
DEFAULT: 15400
portMode poe:poePortmode
(scalar:Enum8)
POE interface's current port mode SELECTION:
0 - Default
1 - never
2 - auto
3 - static
DEFAULT: auto
portPolice poe:poePolice
(scalar:Enum8)
POE interface's current port police action SELECTION:
0 - Default
1 - errdisable
2 - log
DEFAULT: Default
portPriority poe:poePriority
(scalar:Enum8)
POE interface's current port Priority SELECTION:
0 - low
1 - high
DEFAULT: low

Internal Properties
PROPERTY NAME DATA TYPE DESCRIPTION POSSIBLE VALUES
id nw:IfId
(base:IfIndex)
An identifier . Must match first field in the output of show intf brief. Example: Eth1/1 or Vlan100
modTs mo:TStamp
(scalar:Date)
The time when this object was last modified. SELECTION:
0 - never
DEFAULT: never
status mo:ModificationStatus
(scalar:Bitmask32)
The upgrade status. This property is for internal use only. SELECTION:
2 - created
4 - modified
8 - deleted
16 - replaced